A 100 mm length of acetal grows 0.09 mm when it warms by 10 °C. The same length of 30 percent glass-filled nylon 66 grows 0.027 mm along the flow and 0.086 mm across it for the same 10 °C, and polycarbonate grows 0.065 mm. These are straight multiplications of coefficients printed by three makers, and they show that a molded part measured in a warm inspection room reads differently from the same part at the standard 23 °C, by an amount that depends on the resin and the direction.
Temperature is the most common source of measurement disagreement on a molded part, because it is easy to ignore and hard to untangle afterward. The sections below set the coefficients side by side, convert them to length change on a 100 mm dimension, show where the acetal coefficients climb at higher temperature, and write the conditions a dimensional tolerance needs.
Linear Thermal Expansion of Polycarbonate, Glass-Filled Nylon and Acetal
Linear thermal expansion is reported on datasheets as a coefficient, the length change per unit length per degree. The three makers print it by the ISO or TMA method, and they differ in how finely they split it.
| Resin and temperature range | Along the flow | Across the flow |
|---|---|---|
| Polycarbonate, Makrolon 2407, 23 to 55 °C | 0.65E-4 per K (3.6E-5 per °F) | 0.65E-4 per K (3.6E-5 per °F) |
| Acetal, Delrin 500P, 23 to 55 °C | 0.91E-4 per K (5.1E-5 per °F) | 0.93E-4 per K (5.2E-5 per °F) |
| Acetal, Delrin 500P, -40 to 23 °C | 0.79E-4 per K (4.4E-5 per °F) | 0.80E-4 per K (4.4E-5 per °F) |
| Acetal, Delrin 500P, 55 to 160 °C | 1.4E-4 per K (7.8E-5 per °F) | 1.6E-4 per K (8.9E-5 per °F) |
| Nylon 66 with 30 % glass, Ultramid A3WG6, 23 to 55 °C | 0.27E-4 per K (1.5E-5 per °F) | 0.86E-4 per K (4.8E-5 per °F) |
The numbers carry three observations. Polycarbonate and acetal are nearly isotropic in expansion, with almost the same coefficient in both directions, and acetal expands about 40 percent more than polycarbonate. Glass-filled nylon is strongly directional: the transverse coefficient is 3.2 times the flow coefficient (0.86E-4 against 0.27E-4). And acetal’s coefficient is not constant: along the flow it rises from 0.79E-4 below 23 °C to 1.4E-4 between 55 and 160 °C, a factor of 1.8.
A single expansion figure for a plastic is a convenience. The sheets that give more than one figure are telling the buyer that the coefficient changes with temperature and with direction.
Why acetal’s coefficient climbs
Delrin’s guide prints the coefficient in three ranges, and the climb from the low range to the high one runs toward the melting point of 178 °C, where the crystalline polymer softens and each degree adds more length. A glass-filled nylon behaves differently, because the fibers hold the length along the flow, and BASF prints its coefficient for the 23 to 55 °C range only.
Length Change on 100 mm for 2, 10 and 30 °C
Converting coefficients to millimeters gives numbers a buyer can set against a tolerance. The conversion multiplies the coefficient by the length and by the temperature difference. For a 100 mm length, 1E-4 per °C is 0.010 mm per °C.
| Resin and direction | Per 1 °C | 2 °C | 10 °C | 30 °C |
|---|---|---|---|---|
| Polycarbonate, both directions | 0.0065 mm | 0.013 mm (0.0005 in) | 0.065 mm (0.0026 in) | 0.195 mm (0.0077 in) |
| Acetal, along the flow | 0.0091 mm | 0.018 mm (0.0007 in) | 0.091 mm (0.0036 in) | 0.273 mm (0.0107 in) |
| Glass nylon 66, along the flow | 0.0027 mm | 0.005 mm (0.0002 in) | 0.027 mm (0.0011 in) | 0.081 mm (0.0032 in) |
| Glass nylon 66, across the flow | 0.0086 mm | 0.017 mm (0.0007 in) | 0.086 mm (0.0034 in) | 0.258 mm (0.0102 in) |
The 2 °C column is the one that tolerance writers should read first. DuPont’s nylon guide defines post-mold shrinkage as measured at 23 ± 2 °C, and ISO-style test conditions are also stated at 23 °C. A gauge room that holds the part within 2 °C of 23 °C adds up to 0.013 mm to a polycarbonate measurement, 0.018 mm to an acetal one and 0.017 mm to a glass nylon one across the flow, per 100 mm of length. For a tolerance of ±0.05 mm those are fractions of the budget of 26 to 36 percent.
The 30 °C column is for service. Polycarbonate’s printed interval, 23 to 55 °C, is 32 K wide, and the makers’ coefficients are printed for ranges like it. Where a part lives much outside that range, the extra rows of the acetal guide matter, and the coefficient for the real range replaces the room one.
- A part measured at 33 °C in a warm room reads 0.065 mm long on 100 mm of polycarbonate, with no change in the part itself.
- A part from a cold store at 5 °C and measured at once reads 0.14 mm short on 100 mm of acetal, from a temperature gap of 18 °C at the low-range 0.0079 mm per °C.
- A glass nylon part across the flow moves 0.086 mm per 10 °C, 3.2 times the movement along the flow.
Why Gauge Temperature Belongs in the Tolerance
Three things set a molded dimension: its temperature, its moisture state and its age. Datasheets state the first of these. Covestro prints its Makrolon mechanical properties at 23 °C and 50 percent relative humidity, and its shrinkage test specimens are molded under ISO 294. DuPont measures nylon mold shrinkage at 23 °C in the dry-as-molded state after 24 to 48 hours at 23 °C and 50 percent relative humidity. Each of these is a way of saying that the number belongs to a state.
A drawing that omits the state leaves the supplier and the buyer free to measure in different states. Where the gauge room is at 27 °C, a supplier reads acetal parts 0.04 mm larger per 100 mm than a buyer whose room is at 23 °C, a difference that a plus or minus 0.05 mm tolerance cannot absorb. The disagreement is not about quality. It is about two thermometers.
Why does this matter for an order of a few hundred parts? Because the first sample sets the reference for every later one, and an error in its measurement is copied into the whole run. Writing the state once, at the start, protects the lot.
The three states a dimension depends on
- Temperature. The standard of 23 °C, with a stated band such as plus or minus 2 °C.
- Moisture. For nylon, dry as molded or conditioned at 23 °C and 50 percent relative humidity, with the glass grade’s 5.2 to 5.8 percent absorption at saturation in water in mind. Acetal at 0.2 percent in humid air and polycarbonate at 0.12 percent absorb little.
- Age. The time since molding, because the guide’s post-mold shrinkage and the sheet’s optional annealing step both change the part after it leaves the press.
For nylon the second state is the larger of the two nontemperature effects, and this piece gives no numbers for it, because the sources opened give the moisture-dimension curve only for unreinforced nylon 66 and not as a table. The guidance for the buyer is to name the state.
Mating Parts of Different Resins in a Warm Assembly
Differences in expansion between two parts matter more than the expansion of either alone. Take two parts that fit together at 23 °C, each with a 100 mm span, and warm the assembly by 10 °C.
| Pair | Growth of first | Growth of second | Mismatch |
|---|---|---|---|
| Acetal and polycarbonate | 0.091 mm | 0.065 mm | 0.026 mm (0.0010 in) |
| Acetal and glass nylon, along the flow | 0.091 mm | 0.027 mm | 0.064 mm (0.0025 in) |
| Acetal and glass nylon, across the flow | 0.091 mm | 0.086 mm | 0.005 mm (0.0002 in) |
| Polycarbonate and glass nylon, along the flow | 0.065 mm | 0.027 mm | 0.038 mm (0.0015 in) |
The mismatch between acetal and glass nylon depends on how the nylon part is oriented in the assembly. Along the flow the pair drifts apart by 0.064 mm per 10 °C on 100 mm, and across the flow by only 0.005 mm. The same two parts in the same housing fit differently when the nylon part is gated from the other end. A warm environment of 30 °C above the reference triples these figures.
An assembly designer reads this as a rule for clearances and slots. A feature that has to hold a clearance over a temperature range is given that range in its tolerance, with the larger coefficient setting the clearance, and a slot that allows growth is placed on the part with the larger expansion.
Expansion in Service Ranges and the Rows the Acetal Guide Adds
A part spends most of its life away from 23 °C, and the sheets’ split ranges let a buyer estimate the movement from the right row. The arithmetic is the same: coefficient times length times temperature difference.
- Acetal across the flow, 55 to 160 °C. A rise of 105 °C at 1.6E-4 per K gives 1.68 mm on 100 mm.
- Acetal along the flow over the same rise. At 1.4E-4 per K the result is 1.47 mm on 100 mm.
- Acetal along the flow, -40 to 23 °C. A change of 63 °C at 0.79E-4 per K gives 0.50 mm on 100 mm.
- Glass nylon 66 has no row outside 23 to 55 °C on BASF’s page, so its service movement beyond that band is an estimate.
The acetal figure of 1.68 mm across the flow is the largest in the piece. A part of 100 mm that warms from 55 to 160 °C grows by more than a millimeter and a half, and its coefficient nearly doubles between the low and the high range. Anyone who gives such a part one clearance for every temperature has used one number where the part has several.
The printed ranges do not cover every interval. Polycarbonate prints one range, 23 to 55 °C, and an estimate outside it extends the coefficient beyond what the sheet reports, so the result is a guide and not a figure from the maker.
Apparent Shrinkage Caused by Gauge Temperature
Thermal expansion also disturbs the shrinkage measurement that sets the cavity. A part measured warm looks as if it shrank less than it did, and the apparent error is the coefficient multiplied by the temperature gap, expressed in percent.
The error for each case, for a measurement 10 °C above 23 °C, is as follows, set against the shrinkage printed for the resin.
- Polycarbonate. An apparent error of 0.065 points against 0.65 to 0.70 percent printed, about 9 to 10 percent of the printed value.
- Acetal. 0.091 points against 1.9 to 2.0 percent, about 5 percent.
- Glass nylon 66 along the flow. 0.027 points against 0.45 percent, 6 percent.
- Glass nylon 66 across the flow. 0.086 points against 1.09 percent, about 8 percent.
These errors are small beside a printed shrinkage and large beside the effect of a process change. DuPont’s guide gives about 0.1 percent of shrinkage for a 10 MPa change in hold pressure, and a gauge room 10 °C warm adds an error of the same order for acetal and for glass nylon across the flow. A cavity corrected on a first sample measured at 33 °C carries that error into production, in the direction that makes the cavity too small.
A first-sample correction is only as good as the thermometer behind it. The same 0.1 percent that a hold pressure change moves can come from a warm gauge room.
A Worked Tolerance Case for an Acetal Slot
Take a slot in an acetal housing, 60 mm long, with a drawing tolerance of plus or minus 0.05 mm. Its mating part is a polycarbonate cover whose tab is 60 mm long. The contributions that the sheets support are these.
- Process spread. DuPont’s best test part held 0.02 mm on a 49.6 mm diameter, which scales to about 0.024 mm on 60 mm, and the constrained setting held 0.07 mm, which scales to about 0.085 mm.
- Gauge temperature. At 0.0091 mm per °C per 100 mm, a 2 °C band gives 0.011 mm on 60 mm.
- Mating growth. A warm assembly 10 °C above reference opens a mismatch of 0.026 mm per 100 mm between the acetal slot and the polycarbonate tab, which is 0.016 mm on 60 mm.
With the best process, the first two items use 0.035 mm of the 0.05 mm, and the third uses a further 0.016 mm in service, so the pair has no margin at 10 °C of warming. Under the constrained process the spread alone exceeds the tolerance. The case shows how a tolerance that looks generous on a drawing is spent before the part is used, and why the drawing names its measurement conditions and its service range together.
Writing the Measurement Condition on a Drawing
A dimensional tolerance travels with a measurement condition, and a short note settles most of the argument.
- Temperature of measurement, for example 23 ± 2 °C.
- Moisture state, for example dry as molded for nylon, or conditioned at 23 °C and 50 percent relative humidity.
- Time after molding, for example at least 24 hours, and any annealing named.
- Instrument and method, for example a coordinate machine with the part rested for the time needed to reach room temperature.
- Direction of the critical dimension relative to the gate, named on the drawing for glass-filled grades.
The first-sample report records the same five entries against each measured value, so that production parts are compared with the sample in the same state. Since a first-sample report is also the document that closes the shrinkage allowance on an aluminum bridge tool, it carries the temperature and the moisture state on its first page.
A molded dimension is a number with a thermometer attached, and a drawing that writes the thermometer reading beside the tolerance spares both sides an argument later. That is a small addition to a drawing and a large one to its usefulness. For parts in the range of a few to a few thousand pieces, low-volume injection molding is the working form of bridge production.
Sources and Further Reading
- Covestro, Makrolon 2407 ISO Datasheet, edition 18 September 2023
- BASF, Ultramid A3WG6 BK00564 product page, thermal and general properties
- BASF, Ultramid A3WG6 LT BK Product Information, 09/2026
- Delrin, Delrin Design Guide Module III, Table 5, ISO and ASTM properties of Delrin 500P NC010
- DuPont, Molding tips to optimize production of components made with Delrin acetal homopolymer
- DuPont, Zytel and Minlon Nylon Resins Molding Guide, sections on shrinkage and post-mold shrinkage
- ISO, ISO 294-4:2018 Plastics, Injection moulding of test specimens of thermoplastic materials, Part 4, Determination of moulding shrinkage
