PolycarbonateWall ThicknessColor

IEC 60695-2-12 Glow Wire Flammability Index for Molded Parts

The glow wire flammability index read for a buyer: what IEC 60695-2-12 measures, how makers print it by thickness, and what a molded part's file can carry from it.

Flat injection molded light grey plastic test plaques of the same size, one with a small round scorched mark at its centre and two clean.

Covestro’s datasheet for Makrolon 2407 polycarbonate prints three glow wire flammability index values in consecutive rows: 850 °C at 0.75 mm, 875 °C at 1.5 mm and 930 °C at 3.0 mm. The same sheet rates the same resin UL 94 V-2 at 0.75 mm and HB at 2.7 mm. One material, two fire tests, and the numbers move with the wall thickness in each, which is the first thing a buyer has to know before writing “GWFI 850” on a drawing.

IEC 60695-2-12 is the method behind that index. It is a materials test, run on standard specimens rather than on the molded part, and its result is a temperature. This piece reads the standard from its public scope and preview, sets out how its index relates to the other glow wire tests, shows how makers print it on their sheets, and lists what a molded part’s file can and cannot carry from it.

What IEC 60695-2-12 Measures

The scope, printed on the IEC webstore and in the 2021 preview, is short. The standard specifies the details of the glow wire test applied to specimens of solid electrical insulating materials, or other solid materials, to determine the glow wire flammability index, GWFI.

GWFI is defined as the highest temperature, found by the standardized procedure, at which the tested material meets three conditions together:

  • It does not ignite, or if it ignites, it extinguishes within 30 s after the glow wire is removed.
  • It is not totally consumed.
  • Molten drips, if any, do not ignite the wrapping tissue placed below.

The introduction explains the reason for the test. In electrical equipment, overheated metal parts can act as ignition sources, for example through a fault current in a wire, an overloaded component or a bad connection. The glow wire simulates that source: an electrically heated wire pressed against the specimen under controlled laboratory conditions.

The introduction is just as clear about the limit. The test is meant to measure, describe and rank materials. It is not intended to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions, though its results can be elements of a fire hazard assessment that takes the end use into account.

GWFI is a material’s temperature rating against a glowing wire: the hottest wire at which it either does not ignite or puts itself out within 30 s without dripping fire onto the tissue below.

Editions of the Standard and Its Companion Parts

The current text is the third edition, dated 2021-10, prepared by IEC technical committee 89 on fire hazard testing. Its foreword states that it cancels and replaces the second edition of 2010 and its Amendment 1 of 2014, and that it adds terms and definitions for times and durations, with an effect on how the method is applied. It has the status of a basic safety publication under IEC Guide 104, and it is used together with IEC 60695-2-10.

The IEC webstore page for the 2010 edition lists what that second edition had changed from the first: expanded normative references, added definitions, a clause aligned with the IEC 60695-11 series on test programs for material variations, and clarified conditioning, test procedure, observation, evaluation and report clauses.

GWFI is one of four glow wire documents, and the preview names each one’s role.

Table 1. The glow wire parts of IEC 60695 and what each covers, from the IEC 60695-2-12 preview
Document Title in short What it covers
IEC 60695-2-10 Glow wire apparatus and common test procedure The apparatus and the procedure the other parts share
IEC 60695-2-11 Glow wire flammability test for end products (GWEPT) The finished product or part, tested as it is
IEC 60695-2-12 Glow wire flammability index (GWFI) for materials The material, on standard specimens, rated by the self-extinguishing criteria
IEC 60695-2-13 Glow wire ignition temperature (GWIT) for materials The material, rated by the temperature at which it ignites
IEC 60695-1-30 Preselection process How GWFI and GWIT data are used to judge whether materials can meet the end product test

The scope ties these together. GWFI data, with GWIT data, can be used in a preselection process under IEC 60695-1-30 to judge whether a material can meet the requirements of IEC 60695-2-11. A note adds that an appropriate series of preselection tests, as the outcome of a fire hazard assessment, can allow end product testing to be reduced.

The Fire Safety Frame Around the Test

The preview’s introduction places the glow wire tests inside a wider method. IEC 60695-1-10, with its companion IEC 60695-1-11, gives the guidance on reducing fire risk in electrotechnical products during normal operation, reasonably foreseeable abnormal use, malfunction and failure. Their two primary aims are to prevent ignition caused by an electrically energized component and, if ignition happens, to confine the fire within the product’s enclosure.

Their secondary aims are to limit flame spread beyond the enclosure and to limit the harmful effects of fire effluents: heat, smoke, toxicity and corrosivity. Fires started from outside sources that are not electrical are left to the overall fire hazard assessment. The glow wire family addresses the first primary aim, ignition from an overheated part, and that is why it sits beside, not in place of, flame tests such as UL 94 that address how a material burns once alight.

The standard borrows its vocabulary from ISO 13943:2017 and IEC 60695-4, and reproduces the terms it relies on. Combustion is an exothermic reaction of a substance with an oxidizing agent. A flame is a self-sustaining, sub-sonic propagation of combustion in a gas, usually emitting light. A flame event is sustained flaming or glowing combustion. Flammability is the ability of a material or product to burn with a flame under specified conditions. Glowing combustion is burning in the solid phase without flame but with light from the combustion zone.

Those definitions matter when a report is read. A specimen that glows after the wire is withdrawn has not necessarily flamed, and the 30 s criterion in the GWFI definition is about extinction of combustion, whether flaming or glowing. The third edition’s added terms on times and durations, which the foreword says affect how the method is applied, are the reason a report should name the edition it was run to.

How the Test Is Built

The preview prints the table of contents, which shows the parts of the method even where their numbers sit in the paid text. Clause 4 covers test specimens: their preparation, their dimensions, and testing ranges in formulations, with sub-clauses on density, melt flows and filler or reinforcement, and on colour. Clause 7 covers conditioning of the specimens and of the wrapping tissue and wooden board, and the test conditions. Clause 8 sets the procedure, with a table of initial test temperatures, and clauses 9 to 11 cover observations, evaluation and the test report.

The normative references show how the specimens are made. They include ISO 291 for the standard atmospheres used in conditioning, ISO 294 for injection molding of thermoplastic test specimens, ISO 293 for compression molding of thermoplastic specimens and ISO 295 for compression molding of thermosets. A GWFI value on a datasheet is therefore a property of specimens molded under a standard procedure, not of any particular molded part.

The clause on testing ranges in formulations is the one that matters most to a buyer of molded parts. Density, melt flow, filler content and colour are listed as variations the test program has to account for. A rating earned by one formulation does not carry over automatically to a different filler level or to every colour, and the maker’s listing says which variations are covered.

GWFI is measured on molded test specimens prepared to ISO 294 or ISO 293 and conditioned to ISO 291. The rating describes the material at the thicknesses tested, not the part.

How Makers Print GWFI on Their Datasheets

Datasheets print GWFI as a temperature against a thickness, often beside GWIT and UL 94. Two published examples show how much the thickness rows matter.

Table 2. Glow wire and related fire ratings printed by two resin makers
Property (method) Thickness Makrolon 2407 PC (Covestro) LATAMID 66 H2 G/25-GWHF1 PA66 GF25 (LATI)
GWFI (IEC 60695-2-12) 0.4 mm (0.016 in) Not printed 960 °C (1,760 °F)
GWFI (IEC 60695-2-12) 0.75 mm (0.030 in) 850 °C (1,562 °F) 960 °C (1,760 °F)
GWFI (IEC 60695-2-12) 1.5 mm (0.059 in) 875 °C (1,607 °F) 960 °C (1,760 °F)
GWFI (IEC 60695-2-12) 3.0 mm (0.118 in) 930 °C (1,706 °F) 960 °C (1,760 °F)
GWIT (IEC 60695-2-13) 0.75 to 1.5 mm 875 °C (1,607 °F) 775 °C (1,427 °F), also at 0.4 mm
GWIT (IEC 60695-2-13) 3.0 mm (0.118 in) 875 °C (1,607 °F) 825 °C (1,517 °F)
UL 94 Thinnest listed V-2 at 0.75 mm V-0 at 0.4 mm, all technical colors
UL 94 Thickest listed HB at 2.7 mm Not printed separately

Three points come out of the table. First, the index can rise with thickness, as it does for the polycarbonate, or stay flat, as LATI states for its glass-filled, halogen-free polyamide from 0.4 to 3.0 mm. Second, GWFI and GWIT are different numbers for the same material: the polyamide’s index is 960 °C while its ignition temperature is 775 °C at the thinner walls. Third, the UL 94 class does not follow GWFI. The polycarbonate rates only V-2 at its thinnest listed wall while holding a GWFI of 850 °C there.

LATI’s page explains the two glow wire results in plain terms: GWFI measures the material’s ability to self-extinguish after contact with the incandescent wire, and GWIT identifies the temperature at which it tends to ignite. It also states that its values are certified by UL and VDE across thicknesses from 0.4 to 3.0 mm and across all its technical colors, which is the formulation coverage the standard’s clause 4.3 asks about.

The polyamide example also shows how a flame retardant package travels with the rating. LATI describes the grade as a 25 % glass-fiber PA66 with a fully halogen-free flame retardant system, formulated without red phosphorus, and as an improved version of an earlier V-0 grade. The maker adds that results on finished products in glow wire end product tests are satisfactory, which is its own statement about its parts and not a substitute for the end product test a given design may need. A molder substituting a different flame-retardant grade, even of the same base polymer, is substituting a different rating.

Covestro’s sheet places the glow wire rows among other fire and heat rows that an end product standard may ask for separately. For Makrolon 2407 these include a needle flame test under IEC 60695-11-5, from 5 s at 1.5 mm under method K to 120 s at 2.0 and 3.0 mm under method F, a ball pressure test passed at 135 °C under IEC 60695-10-2, an oxygen index of 27 % under ISO 4589-2, and relative temperature indices of 115 to 125 °C under UL 746B at 1.5 mm.

Where a GWFI Requirement Comes From

IEC 60695-2-12 sets no pass level of its own. The temperature a part needs comes from the standard that governs the end product. Plastics Technology reported one example of how that works in practice. A revision of UL 1077, the standard for supplementary protectors used in electrical equipment, allowed materials with a GWFI of at least 750 °C under IEC/EN 60695-2-12 to be used in those devices, and removed the requirement for glow wire end product testing. A material could now be approved on its UL Yellow Card GWFI listing.

The same report described the revision as part of a convergence between UL and IEC standards, with IEC/EN 60947 the standard for low-voltage switchgear outside the Americas. Its supplier source said the change opened miniature circuit breakers, long made in thermoset bulk molding compound, to engineering thermoplastics such as nylons 6 and 46.

LATI names IEC 60335, the household appliance safety series, as the context for its 960 °C grade, and lists connectors, terminal blocks, power distribution, charging and storage systems and internal appliance parts as uses. The appliance standard’s own temperature levels were not opened for this piece, so none is quoted here.

The standard measures the index. The end product standard sets the temperature a part needs and says whether a material listing replaces a test on the part.

What a Molded Part’s File Can Carry

For a molded part, the GWFI belongs to the resin, and the molder’s job is to keep the part inside what the rating covers. The checks that follow from the standard and the makers’ sheets are these:

  1. The grade on the drawing is the exact grade on the maker’s listing, with its GWFI at a thickness equal to or less than the part’s thinnest relevant wall.
  2. The color is covered by the listing. LATI states that its rating applies to all its technical colors; where a sheet does not say so, the color is a formulation variation under the standard’s clause 4.3.
  3. Regrind is limited to what the listing allows. LATI states that UL has certified its grade for use with up to 50 % regrind.
  4. The resin is processed within the maker’s window, so that the molded material stays the material that was rated.
  5. Any glow wire end product test the governing standard requires under IEC 60695-2-11 is done on the part itself, by the party that owns the product’s certification.

Several things the standard leaves open have to be settled outside it:

  • The required temperature, which comes from the end product standard.
  • Whether a material listing is accepted in place of an end product test, which is the end product standard’s decision.
  • The thickness at which the rating has to hold, which comes from the part’s design.
  • The certification of the finished product, which belongs to its maker and not to the resin supplier or the molder.

For a molder, the practical content is traceability. The resin lot, the grade, the color masterbatch if any and the regrind share all need to be recorded against each lot of parts, because each of them is a variation the rating was or was not tested for. A material change in the middle of a run, even to a grade with the same name from another plant, is a change the file has to show.

Fire ratings and declarations belong to the material maker and the product’s certifier, and a molded part carries them only by being made from the listed material within its conditions. In low-volume injection molding for bridge production, the grade with its GWFI listing is fixed on the drawing before the first shot, and the lot record shows that every part was molded from it.

Sources and Further Reading

Request an Injection Molding Quote

Send the 2D drawing and the 3D file, with the quantity and the stage of the project. An engineer replies within 1 working day.

The quote form, the mutual NDA and the private folder for your files are on Protolis Atelier, with Injection Molding chosen.

Request a Quote