CavityShrinkageDatasheet

ISO 20457 Tolerances for Plastic Molded Parts Read for the Buyer

How ISO 20457 is worded for plastic molded parts, what a supplier signs when a drawing cites it, and which items stay outside it for the order to settle.

Injection molded plastic housings and covers in grey and black with snap fits and bosses.

ISO 20457 runs to 28 pages in its first edition, approved on 28 August 2018, and its scope sentence is one line long: the document specifies possible manufacturing tolerances for plastic moulded parts. Everything else a buyer needs from it is in what that line leaves out, and in what the standard’s own scope excludes by name: sink marks, flow structures, roughness and joint lines.

Molded-part drawings point to this standard when they write “general tolerances per ISO 20457” in the title block. The sections below read its scope as the Swedish standards institute publishes it, explain the surface-profile approach the scope describes, set out what a supplier signs when a drawing cites it, and show with maker datasheet numbers why a single general tolerance cannot do the work of a material-specific agreement.

What ISO 20457 Covers for Injection Molded Parts

According to the abstract published by the Swedish Institute for Standards (SIS), ISO 20457 specifies possible manufacturing tolerances for plastic moulded parts, and it covers all integral features with general tolerances, using a surface profile tolerance within a specified datum system. It applies to injection moulding, injection compression moulding, transfer moulding, compression moulding and rotational moulding of non-porous parts in thermoplastics, thermoplastic elastomers and thermosets.

The same page shows that the first edition is withdrawn and replaced by ISO 20457:2026. An old drawing therefore meets a document cited by number and year, and the year decides which text applies. A drawing that says “ISO 20457” with no year leaves the edition to argument, and the safe wording names the edition on the order.

Table 1. Coverage of ISO 20457:2018 as stated in its published scope
Subject In the scope Outside the scope
Processes injection, injection compression, transfer, compression and rotational moulding processes not named in the scope
Materials non-porous thermoplastics, thermoplastic elastomers and thermosets porous parts
Features all integral features, with general tolerances tolerances in a product standard
Tolerance form a surface profile tolerance within a specified datum system none stated for other forms in the abstract
Surface imperfections not covered sink marks, flow structures, roughness, joint lines
Product standards does not replace the tolerance requirements in them where a product standard sets a tolerance, that figure governs

The last row of Table 1 is a guard for buyers in regulated products. If an electrical or automotive product standard prints a dimension for a plug, a latch or a thread, that figure stands, and ISO 20457 does not loosen or tighten it.

ISO 20457 gives general tolerances and manufacturing limits. It leaves the look of the surface, the product standards and any tolerance the parties agree separately to the order.

Surface Profile Tolerance and Datum Systems in Plain Terms

The scope says the standard works through a surface profile tolerance within a specified datum system. Reading that without the standard in hand is possible, because the two ideas are general ones from geometric dimensioning and tolerancing.

A surface profile tolerance defines a zone around the nominal surface of the CAD model. The molded surface is acceptable where it lies inside the zone, and the zone’s width is a single number for the feature. A datum system fixes the part in space for measurement, with a primary, a secondary and a tertiary datum, so that the profile is measured from a stated frame and not from wherever the part sits on the gauge table. Together they replace a pile of plus and minus dimensions on a drawing with one model and one frame.

For a molded part this is practical. A cavity is machined from the model, the part comes out smaller by the shrinkage, and a profile zone measured from agreed datums asks whether the surfaces are where the model puts them. Chained plus-minus dimensions can hide an error that a profile zone shows.

  • A datum system is chosen on features that stay stable after molding, so datum faces are not the thinnest walls or the ends of long cantilevers.
  • The profile zone is stated per feature or per face, and the general zone for all other faces is stated once in the title block.
  • The measuring method, coordinate machine or optical scan, and the temperature of measurement are stated or agreed.

Why measuring conditions travel with the tolerance

A molded dimension depends on when and at what temperature it is read. DuPont’s nylon molding guide defines mold shrinkage as measured at 23 °C on a dry-as-molded specimen after 24 to 48 hours at 23 °C and 50 percent relative humidity. Post-mold shrinkage in the same guide is measured at 23 ± 2 °C after annealing. Covestro’s polycarbonate sheet records a linear expansion of 0.65E-4 per K between 23 and 55 °C, so a 100 mm part read at 33 °C is 0.065 mm larger than at 23 °C. A tolerance with no stated conditions is a tolerance read at the inspector’s temperature, and on a 100 mm acetal part a 10 °C difference in the gauge room moves the reading by 0.10 mm, using the 1.0E-4 per °C coefficient on DuPont’s sheet.

What a Supplier Signs When a Drawing Cites ISO 20457

A drawing that cites a general tolerance standard creates an agreement with several parts, and each part has a signature.

  • Edition. The order names ISO 20457 with its year of publication.
  • Scope of the general tolerance. The title block says which features carry the general tolerance and which carry direct tolerances written on the drawing.
  • Datum system. The drawing defines the datum features, or the supplier proposes them and the buyer approves before the tool steel is cut.
  • Measurement. The method, the temperature and the time after molding are stated.
  • Sample. A first-article sample is measured against the drawing and signed off by both sides.

Of these five the sample is the one the standard cannot supply. The standard describes possible manufacturing tolerances, which are ranges a process can hold in general, and a part holds those ranges only after a cavity has been cut with the right shrinkage allowance and the process has been run to a stable state. A tolerance written before the first sample is a hope, and a tolerance confirmed on the first sample is a specification.

Direct tolerances against general tolerances

A general tolerance covers every feature that carries nothing else. Written on a particular dimension, a direct tolerance overrides the general one for that feature. The usual split puts direct tolerances on features that mate with another part, such as a hole for a pin or a width for a slot, and leaves the free surfaces to the general tolerance.

The tighter the direct tolerance, the more the molded part depends on process stability. DuPont’s acetal tips show the effect on a 49.5 mm outer diameter: variation of 0.02 mm with an optimized process and 0.7 mm with a poor one on the same material and tool. A direct tolerance of 0.05 mm on that diameter can be held in one process and missed by an order of magnitude in another.

Why One General Tolerance Cannot Serve Every Material

Any general tolerance table gives one width for a size range, while the material beneath that width does not behave uniformly. Maker datasheets show how large the differences are, and Table 2 takes the molding shrinkage printed on three sheets under ISO 294-4, the test that measures shrinkage on a molded plaque, and converts each to the length change on a 100 mm dimension.

Table 2. Shrinkage on a 100 mm dimension from the ISO 294-4 values printed on three maker datasheets
Resin Along the flow Across the flow Gap between directions Source
Polycarbonate, Makrolon 2407 0.65 mm (0.026 in) 0.70 mm (0.028 in) 0.05 mm (0.002 in) Covestro sheet, 60 by 60 by 2 mm at 500 bar
Nylon 66 with 30 % glass, Ultramid A3WG6 LT BK 0.45 mm (0.018 in) 1.09 mm (0.043 in) 0.64 mm (0.025 in) BASF sheet
Acetal homopolymer, Delrin 500P 2.0 mm (0.079 in) 1.9 mm (0.075 in) 0.1 mm (0.004 in) Delrin data sheet

Three points come out of the table. One is the scale: acetal gives up 2 mm on a 100 mm dimension and polycarbonate gives up 0.65 mm, so the same mold-maker’s allowance is three times larger on one than on the other. Another is the direction gap: glass-filled nylon gives 0.64 mm of difference between along and across, on a flat part, where polycarbonate gives 0.05 mm. A square plate in glass nylon is not square after molding unless the cavity was cut with different allowances in the two directions. Last, none of these numbers is a tolerance. They are the central values from a test plaque, and a part’s actual shrinkage differs with its thickness, gate and process.

A general tolerance that is right for polycarbonate at 100 mm may be unreachable for glass nylon at the same size, because the material alone puts 0.64 mm of anisotropy into a part before any process variation. This is the strongest argument for adding a material-specific line to the order. This also explains why a prototype cut as machined plastic can hold a tighter tolerance than the molded part will: the cutter sets the machined size directly, while the molded size is set by shrinkage.

From a Shrinkage Allowance to a Cavity Dimension

A cavity is cut larger than the part by the shrinkage allowance, and the arithmetic is simple enough for a buyer to check a toolmaker’s number. For a shrinkage fraction s, the cavity dimension is the part dimension divided by (1 minus s). Using the central values of Table 2 on a 100 mm part dimension:

  • Polycarbonate at 0.65 percent gives a cavity of 100.65 mm along the flow and 100.70 mm across it.
  • Glass-filled nylon 66 at 0.45 percent along the flow gives 100.45 mm, and at 1.09 percent across the flow gives 101.10 mm.
  • Acetal at 2.0 percent along the flow gives 102.04 mm, and at 1.9 percent across the flow gives 101.94 mm.

A toolmaker who cuts one allowance for the whole glass nylon part is cutting it wrong in one of the two directions by about 0.64 mm per 100 mm. DuPont’s molding guide also shows how far a single process setting moves the number. For nylons it says the highest possible holding pressure is applied to diminish mold shrinkage, usually around 90 MPa, and that a variation of 10 MPa will result in about 0.1 percent variation in shrinkage. On a 100 mm dimension that is 0.1 mm from a pressure setting alone, which is comparable with the gap between a fine and a general tolerance on many small parts.

A shrinkage allowance is a bet on the process. The cavity is cut once, and the first samples show whether the bet was right, so the allowance is written down together with the process conditions it assumes.

The practical outcome is that the first sample carries information the standard cannot. It shows the real shrinkage of the real part, in each direction, with the gate where it is and the pressure that was used. A toolmaker working in aluminum can correct a cavity after that sample, and the order is agreed so that this correction is expected and not a surprise.

A Sequence for Agreeing Tolerances Before the Tool Is Finished

A buyer can run the agreement in five steps, and each step is a document or a physical object.

  1. The drawing cites the standard by number and year and states the datum system.
  2. The toolmaker states the shrinkage allowance used for each direction and the datasheet value behind it.
  3. The first samples are molded at the agreed process conditions and measured at the agreed temperature and time.
  4. The measurement report is compared with the drawing, direct tolerances are confirmed or revised, and the cavity is corrected if the allowance missed.
  5. A second sample confirms the correction, and the approved sample and its measurement report become the reference for the run.

A datum choice shows the point on a real shape. Take a flat glass-filled nylon cover gated at one end. If the datum is the long edge, the part is measured from the edge that shrinks least, 0.45 percent along the flow, and the far side is read across the direction that shrinks 1.09 percent. Take the gated end as datum instead and the roles swap and the same part shows different deviations. Neither choice is wrong, but the two readings differ, which is why the datum system belongs on the drawing before the first sample and not in the inspector’s habits.

Where a step is skipped the cost shows up later as a disagreement about whether parts are good. A written chain from datasheet to allowance to sample to approved reference turns that disagreement into a comparison.

What the Standard Leaves Open and How to Close It

The scope excludes surface imperfections by name, which makes four things a buyer has to settle elsewhere.

Table 3. Items outside ISO 20457 and the order document that closes each
Open item Where it is settled Typical reference
Sink marks A cosmetic acceptance statement for named faces A sample plate or limit sample
Flow structures and joint lines The same acceptance statement, with faces ranked A limit sample
Surface roughness A finish grade on the drawing SPI grade or a named texture
Tolerance in a product standard The product standard itself The standard’s own clause
Tolerances tighter than general A direct tolerance on the drawing The T1 sample measurement

Fixing these items early also protects the bridge run itself, because a disagreement over a cosmetic limit found at delivery cannot be settled by the standard and has to be settled by whatever was signed before the tool was cut. The common thread in Table 3 is the sample. Each open item closes with something that exists physically, a plate, a limit sample or a measured first article, and each is agreed before the production tool is finished. An aluminum bridge tool lends itself to this order of work, because the first samples arrive while the tool can still take a cavity correction. DuPont’s acetal tips give the order of correction: check the gate and the process first, then correct the cavity if the dimensions still miss, and never compromise the process settings to hit a dimension.

  • A shrinkage allowance is set from the datasheet value, the part’s thickness and the gate position, and it is checked on the first sample.
  • A direct tolerance is accepted only after the first sample proves it can be held.
  • A change in resin grade, color or process settings after sign-off reopens the dimensions it affects.

An agreed general tolerance, a named edition, a datum system and a signed sample cover most of what ISO 20457 asks a drawing to say. For parts in the range of a few to a few thousand pieces, low-volume injection molding is the working form of bridge production.

Sources and Further Reading

Request an Injection Molding Quote

Send the 2D drawing and the 3D file, with the quantity and the stage of the project. An engineer replies within 1 working day.

The quote form, the mutual NDA and the private folder for your files are on Protolis Atelier, with Injection Molding chosen.

Request a Quote