Meaning
The cavity is the hollow in a mold that gives a molded part its shape, cut larger than the part by the resin’s shrinkage. A tool can carry one cavity or several, and each forms a part with every shot. The part copies the cavity surface, and the cavity walls hold the part while it cools. Most corrections a bridge run needs end as a few tenths of a millimeter cut into the cavity.Cavity Dimension
A toolmaker cuts the cavity to the part dimension divided by one minus the shrinkage fraction. For polycarbonate at 0.6 percent, a 100 mm (3.94 in) part needs a 100.60 mm cavity. Glass-filled nylon 66 needs 100.30 mm along the flow and 101.11 mm across it. Acetal needs 102.04 mm along the flow. One allowance cut for a whole glass nylon part is wrong in one direction by 0.8 mm per 100 mm.Read More
Effect on Hours
Parts per hour equal 3,600 divided by the cycle in seconds, times the cavity count, at full uptime. At a 26 second cycle, 5,000 parts need about 36 hours with one cavity. With four cavities they need about 9 hours. More cavities also ask for more clamp force and a bigger shot. A 600 kN (65 ton) press at 90 MPa (13,050 psi) holds about 6,700 mm² (10.3 in²) of projected area. That figure includes the runner and is an upper bound. Real cavity pressure sits below the pressure at the screw, so flow analysis sets the final number.Cooling and Release
A part left in the cavity is held by the walls and cores while it shrinks. DuPont’s acetal test part shows the cost of that hold. Cooling 15 seconds in the mold after full packing widened the spread of its 49.6 mm (1.95 in) diameter. The spread went from ±0.02 mm to ±0.07 mm. Acetal is therefore ejected hot and cooled in air, where it shrinks without constraint. A part has to leave the cavity on the intended side. One that sticks to the cavity half instead of the core points to draft, polish or temperature. DuPont recommends 0.5° to 1° of draft per side for nylon, and up to 2° for softer, more elastic resins. Covestro suggests different temperatures on the two mold halves to hold the part on the chosen side.Correction
DuPont corrects the cavity only after the gate and the process have been checked. It never compromises the process settings to hit a dimension. An aluminum cavity can be recut, welded or enlarged after the first samples. That is the practical reason a bridge tool is made of it. A second sample confirms the correction, and the approved sample becomes the reference for the run. A first sample measured 10 °C warm misleads the correction, and the cavity ends up too small.Surface and Wear
The molded surface copies the cavity surface, so a clear part is only as clear as the polish it met. The SPI grades name that finish, from A-1 at an Ra of 0.012 to 0.025 µm to D-3 at 3.2 to 18 µm. A nickel-boron coating of 5 to 8 µm (0.0002 to 0.0003 in) is thicker than every polished grade is rough. The order of polishing and coating is therefore agreed with the toolmaker. Galling from excessive temperature and injection pressure damages the cavity surface, and every later part copies the damage. Each cavity wears with every shot. A dimension that moves one way across successive lots is the usual sign of a cavity or core wearing away. Cavities and runners are vented at the parting line and at the ejectors. A vent that clogs shows as a burn mark at the end of flow.Sampling by Cavity
ISO 2859-1 calls for a stratified sample when a lot divides into sensible sub-lots. Each cavity of a multi-cavity tool is such a stratum, so the sample is drawn across the cavities in proportion. The cavity is marked on the part, or the sample cannot be stratified. A first article records the cavity each measured part came from.