Meaning
Part weight is the weight of a molded part with runner and sprue removed, used to find the hold time and to watch a run. A part that weighs less than its sister parts holds less plastic. It is more likely under-packed than mismeasured. Weighing takes a minute on a laboratory balance, which makes it the cheapest process record there is.Weight Study
DuPont’s nylon guide gives the method. Total cycle time stays constant for the whole study, so that the melt temperature does not drift. Parts are molded at hold times 0.5 to 1.0 seconds apart, depending on the resolution wanted. Each part is weighed without its runner and sprue. Weight is then plotted against hold time. The right hold time is where the weight first stops rising. Shrinkage reaches its minimum at the same hold time, so a dimensional check on those parts confirms the reading. Beyond that point more hold adds nothing, because the gate has frozen, and it takes cycle time from the line. A weight that never reaches a plateau means the gate freezes before the part is packed. The correction then sits at the gate, not at the machine.Read More
Acetal Case
DuPont’s Delrin tips show the same pattern on a wear-test part. An optimum packing time of 15 seconds gave the highest part weight and the least warpage. With 2 seconds of cooling that part held its 49.6 mm (1.95 in) diameter to ±0.02 mm. Trial 2 used the same 26 second cycle with 10 seconds of packing and varied by ±0.7 mm. The cycle did not change and the quality did.Thickness Effect
Packing time does not scale in proportion to the wall. DuPont’s plot shows packing time per millimeter rising as thickness rises. The Delrin 500P sheet’s 8 s/mm is therefore an average, and thicker walls sit above it. A 2 mm rib and a 6 mm boss do not need three times the hold, because the thick section needs a disproportionate share. The optimum is found by weighing parts, not by reading one figure off a sheet.Wear Gauge
A weight study repeated during a run becomes a wear gauge. A gate that wears larger changes the packing, so a mold can give a heavier or lighter part before its cavity shows visible damage. A gate, a shut-off or a check ring that has changed shows as weight drifting at a hold time that used to give a plateau. In a lot record, weight is the earliest sign of that change, long before a dimension leaves its limit.Shrinkage Meter
Weight stands in for shrinkage on the press. A part from a short hold shrinks more, and its dimensions will not match later production parts. DuPont’s nylon guide sets the hold time where weight peaks because shrinkage is lowest there. A dimension controlled by weight is checked by weighing, which a toolroom does in a minute. A buyer reviewing first samples can ask for the plot of part weight against packing time. That plot shows the process was set before the cavity was touched. DuPont’s order of correction depends on it, because gate and process come before any cavity change. In a lot record, part weight at the set hold time shows whether the part is packed and the gate is behaving.Record
A start-up adjusts first for appearance and then for maximum part weight. The pack time is then fixed by the weight study. A cycle quoted before that study is an estimate, and one quoted after it is a measurement. A shrinkage figure on a first sample counts only if its hold time sits on the plateau. The first-article record carries the hold time and the part weight at which the plateau was reached. Later lots are compared with that weight. A trial report that lists hold time without the weights behind it has skipped the measurement that makes the number repeatable. A lot whose weight holds the plateau is a lot packed the same way.